{"id":8505,"date":"2026-11-16T05:20:52","date_gmt":"2026-11-16T05:20:52","guid":{"rendered":"https:\/\/koitorhardware.com\/?p=8505"},"modified":"2026-11-16T05:20:54","modified_gmt":"2026-11-16T05:20:54","slug":"spot-welding-symbol-drawing-buyer-guide","status":"publish","type":"post","link":"https:\/\/koitorhardware.com\/de\/spot-welding-symbol-drawing-buyer-guide\/","title":{"rendered":"Spot Welding Symbols: Read Size, Count, Pitch and Process Before RFQ"},"content":{"rendered":"<p>A spot welding symbol is only one part of a drawing callout; a buyer must read it under the drawing\u2019s stated convention and together with the joint geometry, dimensions, process notes, and acceptance requirements. Before requesting a quotation, confirm which standard and edition apply, where the arrow identifies the joint, what size or strength is called out, how many welds are required, whether spacing or pitch is shown, and what process or inspection notes govern. A circular mark alone does not provide a complete production specification.<\/p>\n<h2>What Does a Spot Welding Symbol Communicate?<\/h2>\n<p>A welding symbol helps transmit design information from the drawing to fabrication and inspection teams. The specific meaning depends on the referenced system and the symbol\u2019s location in relation to the reference line, arrow, dimensions, tail, and other notes. Do not treat a symbol as a sketch of the finished weld or infer a process from its appearance without checking the legend and governing standard.<\/p>\n<p>For a sourcing buyer, the symbol is a prompt to connect four questions:<\/p>\n<ol>\n<li><strong>Which joint is intended?<\/strong> The arrow and drawing geometry should identify the members and their relationship.<\/li>\n<li><strong>What weld result is required?<\/strong> The symbol and dimensions may communicate type, size, strength, count, spacing, or other specified information depending on the convention.<\/li>\n<li><strong>Which process or supporting documents apply?<\/strong> The drawing may refer to a procedure, standard, material note, or process in a symbol tail or separate specification.<\/li>\n<li><strong>How will acceptance be decided?<\/strong> The symbol itself does not automatically define every tolerance, test method, sample plan, or visual criterion.<\/li>\n<\/ol>\n<p>The American Welding Society\u2019s <a href=\"https:\/\/pubs.aws.org\/p\/1999\/a242020-standard-symbols-for-welding-brazing-and-nondestructive-examination\" rel=\"nofollow noopener\" target=\"_blank\">A2.4:2020 standard description<\/a> says the standard establishes a method for specifying certain welding, brazing, and nondestructive-examination information by symbols. The <a href=\"https:\/\/pubs.aws.org\/Download_PDFS\/2__A2_4_2020_PV.pdf\" rel=\"nofollow noopener\" target=\"_blank\">published AWS A2.4:2020 foreword<\/a> also states that the publication does not dictate weld design requirements, tolerances, or dimensions. The design authority must provide those requirements rather than expecting production personnel to invent them.<\/p>\n<p>This distinction matters in RFQs. A shop may be able to interpret a symbol under one convention, but that does not authorize it to choose the joint strength, invent dimensions, or decide whether an undocumented weld is acceptable. The buyer should route design intent to the responsible engineer and make the approved interpretation visible in the controlled drawing or specification.<\/p>\n<h2>Which Drawing Convention Should Be Used Before Reading the Callout?<\/h2>\n<p>Start with the general notes, title block, drawing legend, contract specification, and customer requirements. Identify whether the drawing uses AWS, ISO, or another stated convention and note its edition or national adoption. Do not combine a familiar AWS example with an ISO callout as if all placements and notations were interchangeable.<\/p>\n<p>The International Organization for Standardization describes <a href=\"https:\/\/www.iso.org\/cms\/%20render\/live\/en\/sites\/isoorg\/contents\/news\/2020\/01\/Ref2471.html\" style=\"color:#0B5CAD;text-decoration:underline;\" rel=\"nofollow noopener\" target=\"_blank\">ISO 2553<\/a> as a standard for symbolic representation of welded joints on technical product documentation. Its public page can show draft or edition information that changes over time; a buyer should confirm the adopted current edition in the contract and applicable national rules rather than relying on a search snippet. AWS A2.4 and ISO 2553 are separate conventions. A project should designate one governing system or clearly explain how referenced systems are reconciled.<\/p>\n<p>Before quoting, ask:<\/p>\n<ul>\n<li>Is a welding-symbol standard named in the drawing or purchase specification?<\/li>\n<li>Which edition and local adoption apply to this order?<\/li>\n<li>Are all symbols on the drawing consistent with that convention?<\/li>\n<li>Does the drawing include a legend for nonstandard marks or customer-specific abbreviations?<\/li>\n<li>Are dimensions expressed in metric or inch units, and is that system consistent across views?<\/li>\n<li>Is a referenced detail, weld schedule, process note, or procedure available to the supplier?<\/li>\n<li>Who can answer an ambiguous or contradictory callout?<\/li>\n<\/ul>\n<p>If the drawing omits the convention, do not silently select one based on the supplier\u2019s location or a prior project. Ask the buyer\u2019s engineering owner to identify the governing method and issue a controlled revision or written clarification. That response should accompany the same drawing revision used for quotation, sampling, production, and inspection.<\/p>\n<h2>How Should Buyers Read Size, Count, Pitch, and Process Notes?<\/h2>\n<p>Read each marked field in context and verify its unit, placement, and referent in the applicable standard. A field that appears to be a size, count, spacing, or process note may have a different meaning under another convention or a customer legend. The following table is a checklist of questions, not a substitute for the standard\u2019s exact symbol definitions.<\/p>\n<div class=\"wp-block-table koitor-responsive-table\" style=\"max-width:100%;overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;overflow-wrap:anywhere;\">\n<thead>\n<tr>\n<th>Drawing field or note<\/th>\n<th>Buyer interpretation question<\/th>\n<th>What it does not establish by itself<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Joint location and arrow<\/td>\n<td>Which members and joint line does the arrow identify?<\/td>\n<td>It does not prove that the shown geometry is manufacturable or that all sides are included.<\/td>\n<\/tr>\n<tr>\n<td>Basic spot-weld symbol<\/td>\n<td>Which weld type is required under the named convention?<\/td>\n<td>It does not by itself state every process parameter or finished-product acceptance rule.<\/td>\n<\/tr>\n<tr>\n<td>Size or strength information<\/td>\n<td>What dimension, strength, or other criterion is identified and in which units?<\/td>\n<td>It does not authorize production to choose a value missing from the drawing.<\/td>\n<\/tr>\n<tr>\n<td>Number of welds<\/td>\n<td>Does the quantity refer to one feature, one joint, a pattern, or an assembly?<\/td>\n<td>It does not define the exact coordinates if a pattern or location datum is absent.<\/td>\n<\/tr>\n<tr>\n<td>Pitch or spacing<\/td>\n<td>Is a center-to-center spacing, pattern, or distribution specified under the selected convention?<\/td>\n<td>It does not automatically resolve edge distances, end conditions, or tolerance.<\/td>\n<\/tr>\n<tr>\n<td>Process designation or tail<\/td>\n<td>Is a process, specification, procedure, or other reference named?<\/td>\n<td>It does not prove that a supplier has the equipment or qualification unless separately verified.<\/td>\n<\/tr>\n<tr>\n<td>Supplementary note<\/td>\n<td>Are examination, contour, sequence, or other requirements called out?<\/td>\n<td>It does not establish a test plan that is not stated or referenced.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Do not copy illustrative values from a symbol chart into a production drawing. AWS materials show how fields can be arranged and interpreted, but examples are illustrative; the designer must state the actual requirement for the product. An example number printed beside a symbol is not a tolerance, minimum weld size, universal strength, or process recipe.<\/p>\n<p>The AWS <a href=\"https:\/\/app.aws.org\/mwf\/attachments\/50\/207450\/WeldSymbolsProof.pdf\" rel=\"nofollow noopener\" target=\"_blank\">welding symbol chart<\/a> identifies drawing elements such as the reference line, arrow, tail, weld type, number of spot welds, and pitch in its chart. Use the chart as an orientation aid only and consult the governing published standard for the controlled project interpretation. The exact callout and the project\u2019s design requirements must be reviewed together.<\/p>\n<figure class=\"wp-block-image size-large koitor-blog-image\"><img decoding=\"async\" src=\"https:\/\/koitorhardware.com\/wp-content\/uploads\/2026\/11\/K1667-process-delivery.webp\" alt=\"Buyer and fabricator compare a weld drawing with sheet-metal joint samples\" style=\"width:100%;max-width:960px;height:auto;display:block;margin:0 auto;\" \/><\/figure>\n<h2>What Information Is Often Missing From a Spot-Weld Drawing?<\/h2>\n<p>A spot welding symbol can be valid yet insufficient for a quotation or inspection if the drawing leaves related design decisions open. The buyer should look for complete joint identification, not simply a recognizable mark. Common gaps include unclear member orientation, unspecified location datums, units not stated, contradictory drawing notes, missing material thickness, an unreferenced process note, or no stated acceptance criteria.<\/p>\n<p>Check the drawing as a complete definition:<\/p>\n<ul>\n<li><strong>Part geometry:<\/strong> Are the component shapes, overlap, stack-up, access, and orientation visible in the view or referenced detail?<\/li>\n<li><strong>Material and thickness:<\/strong> Are the materials and relevant thicknesses controlled by the bill of materials or drawing?<\/li>\n<li><strong>Joint identification:<\/strong> Can the production team identify which surfaces and members form the joint?<\/li>\n<li><strong>Weld location:<\/strong> Is the pattern dimensioned from datums, edges, or a controlled fixture reference?<\/li>\n<li><strong>Quantity and distribution:<\/strong> Is the weld count assigned to one joint or to a complete assembly, and is the pattern clear?<\/li>\n<li><strong>Process ownership:<\/strong> Does the drawing specify a process or refer to a procedure without assigning a revision?<\/li>\n<li><strong>Acceptance:<\/strong> Are visual, destructive, nondestructive, or functional checks defined by the responsible design authority where required?<\/li>\n<li><strong>Change control:<\/strong> Is there a revision process for clarifying the symbol before the first sample or production run?<\/li>\n<\/ul>\n<p>The drawing\u2019s silence is not a hidden instruction. Production personnel should not guess what a design engineer meant by \u201csufficient weld,\u201d \u201ccontinuous,\u201d or \u201ctypical\u201d unless those terms are explicitly defined by the project standard and drawing notes. If a requirement is unclear, issue a query and preserve the answer with the revision.<\/p>\n<p>An engineering clarification should state the approved interpretation, the drawing features it applies to, any required update to dimensions or notes, and who approved the decision. If the supplier\u2019s quotation depends on an assumption, list that assumption and request confirmation before sample release. That approach prevents a quote comparison from treating two different interpretations as the same scope.<\/p>\n<h2>How Can Buyers Turn the Symbol Into a Complete RFQ?<\/h2>\n<p>Translate the callout into a structured request that the design owner, supplier, and quality team can all review. Include the drawing and revision, standard and edition, joint detail, material and thickness, weld location and quantity, process requirement if specified, any inspection references, and the decision owner for questions. Attach the referenced detail or weld schedule rather than citing an unavailable document.<\/p>\n<div class=\"wp-block-table koitor-responsive-table\" style=\"max-width:100%;overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;overflow-wrap:anywhere;\">\n<thead>\n<tr>\n<th>RFQ attachment or field<\/th>\n<th>Buyer should provide<\/th>\n<th>Supplier should confirm<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Controlled drawing<\/td>\n<td>Part number, revision, units, and governing symbol convention<\/td>\n<td>Receipt of the correct file and any unreadable or conflicting callout<\/td>\n<\/tr>\n<tr>\n<td>Joint detail<\/td>\n<td>View or section identifying member stack and location<\/td>\n<td>Access, fixturing, and interpretation assumptions for quotation<\/td>\n<\/tr>\n<tr>\n<td>Material definition<\/td>\n<td>Material grade and thickness from approved records<\/td>\n<td>Any missing or incompatible material information before sample work<\/td>\n<\/tr>\n<tr>\n<td>Weld schedule<\/td>\n<td>Required count, locations, size or strength criteria as designed<\/td>\n<td>Whether the listed features can be quoted and inspected as written<\/td>\n<\/tr>\n<tr>\n<td>Process reference<\/td>\n<td>Named process\/procedure only where the design owner specifies it<\/td>\n<td>Applicable capability or subcontractor boundary, without implying unverified capacity<\/td>\n<\/tr>\n<tr>\n<td>Acceptance plan<\/td>\n<td>Criteria, sampling, inspection method, and approval role<\/td>\n<td>Which records or sample checks can be supplied for the agreed scope<\/td>\n<\/tr>\n<tr>\n<td>Clarification log<\/td>\n<td>Approved answers and dates<\/td>\n<td>Confirmation that quote and sample use the clarified revision<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Keep design values separate from quotation assumptions. If the supplier suggests a change to weld count, location, size, material, fixture, or sequence, document it as a proposal and obtain the buyer\u2019s design approval before incorporating it into the released product. A lower quote based on fewer or differently located welds is not comparable unless that changed design has been approved.<\/p>\n<p>When several files govern the same assembly, name their revision and precedence in the RFQ. A drawing, weld schedule, CAD model, purchase specification, and sample may disagree. Do not assume that the most recently emailed attachment overrides a released drawing unless the buyer\u2019s change process says so. Ask the design owner which document controls each feature and request a coordinated revision if the conflict affects production or acceptance. Keep superseded files identified as obsolete so a shop does not quote one interpretation and build another.<\/p>\n<p>Use a short clarification log with one row per open point: drawing zone, current callout, uncertainty, proposed question, responsible engineering contact, response, approved revision, and date. This is especially useful when multiple weld features are visually similar but have different purposes. A supplier can answer whether a feature is accessible or how it interprets the stated symbol, but only the authorized design owner can approve a change to the required joint result.<\/p>\n<p>When the request affects quotation timing, distinguish a preliminary budget estimate from a firm production quote. A supplier may identify an assumption for an unresolved pattern, but the buyer should label that figure as provisional and prevent it from becoming a released purchase requirement. Close the technical point before comparing final prices, lead times, or sample commitments. This keeps commercial approval from accidentally turning a temporary engineering assumption into the only recorded definition of the joint.<\/p>\n<p>Before a sample is released, compare the clarified drawing against the physical sample. Confirm that the sample uses the intended material stack, joint orientation, weld locations, and process scope. If a sample uses a temporary fixture or a different material for demonstration, record that limit. Do not treat a convenient prototype as the final acceptance specimen when the geometry or joint definition is materially different.<\/p>\n<p>For repeat orders, carry the same controlled reference into the purchase order, sample record, inspection plan, and supplier change notice. If the buyer changes the number or location of welds, update the pattern and acceptance documentation together. Changing only one drawing note can leave the production and inspection teams following different versions of the requirement. A traceable revision makes later nonconformance review more specific and reduces disputes about which callout was approved.<\/p>\n<p>For product samples, identify which features are prototypes, which are intended to match production, and what acceptance evidence is expected. A sample can help review fit and appearance, but it does not establish production repeatability or prove a specified weld strength unless an appropriate design and test plan says so. Do not use an image of a sample or a visual bead description as a substitute for a controlled requirement.<\/p>\n<h2>How Should Quality Teams Verify the Weld Requirement?<\/h2>\n<p>Verification should follow the drawing and acceptance plan. A visual check can reveal some visible conditions but cannot establish every internal or strength characteristic. If a buyer requires testing, the design authority should define the applicable method, sample configuration, frequency, conditioning, and pass\/fail rule. Those details must not be invented by a blog article or supplier on behalf of the customer.<\/p>\n<p>Build a traceable check sequence:<\/p>\n<figure class=\"wp-block-image size-large koitor-blog-image\"><img decoding=\"async\" src=\"https:\/\/koitorhardware.com\/wp-content\/uploads\/2026\/11\/K1667-checklist-delivery.webp\" alt=\"Unmarked drawing and welded coupons arranged for RFQ clarification\" style=\"width:100%;max-width:960px;height:auto;display:block;margin:0 auto;\" \/><\/figure>\n<ol>\n<li>Confirm the part number, drawing revision, material, and weld-callout convention.<\/li>\n<li>Confirm that the correct joint and orientation were selected on the sample or production part.<\/li>\n<li>Verify weld count and location against the controlled pattern or datums.<\/li>\n<li>Record any required visual or dimensional checks using the stated criteria.<\/li>\n<li>Perform additional testing only when the design or purchase specification requires it and the method is defined.<\/li>\n<li>Link records to the lot, date, process route, and any approved deviation.<\/li>\n<li>Escalate ambiguous results to the design or quality owner instead of making an informal acceptance rule.<\/li>\n<\/ol>\n<p>Do not infer strength from the number of welds, visible appearance, machine display, or a process label. Likewise, a test of one sample does not automatically prove every part in a lot or every geometry in a product family. The meaning and scope of evidence depend on the agreed method and sampling plan.<\/p>\n<p>For a wire basket or small bathroom-hardware assembly, weld location may interact with visible faces, coating coverage, component position, and inspection access. Those interactions can be included in the product drawing and appearance sample. Koitor\u2019s separate coverage of expulsion in wire baskets and intermittent-weld notation addresses different questions; this article is limited to reading and completing the spot-weld callout before RFQ.<\/p>\n<h2>How Can an OEM Factory Use the Drawing Clarification?<\/h2>\n<p>Once the design intent is explicit, an OEM factory can review the drawing, sample, weld access, fixture considerations, visible faces, finish route, and packaging requirements within its confirmed scope. Koitor Hardware is a family-owned custom metal hardware factory focused on bathroom and home-storage hardware. Approved company facts support discussion of welding and fabrication processes, sample development, customization from buyer drawings or physical samples, assembly, and packaging preparation. They do not establish an exact welding machine capacity, certified laboratory, or guaranteed weld performance for an unreviewed design.<\/p>\n<p>For a project conversation, send the released drawing, bill-of-material references, symbol convention, material thicknesses, approved sample if available, and the unresolved question. Identify which fields are design requirements and which are supplier suggestions. If the engineering owner authorizes a revision, share the updated controlled file before quotation or production proceeds.<\/p>\n<p>The factory and buyer can then separate drawing interpretation from process feasibility. The buyer owns the product design and acceptance criteria; the manufacturer clarifies how the quoted scope maps to the drawing, flags missing information, and confirms which operations are included or sourced from another party. That division protects both schedule and quality because no one needs to guess at a critical joint requirement.<\/p>\n<p>Review the <a href=\"https:\/\/koitorhardware.com\/de\/oem-home-storage-hardware-manufacturer\/\" style=\"color:#0B5CAD;text-decoration:underline;\">Umfang der OEM-Fertigung von Hardware f\u00fcr die Heimdatenspeicherung<\/a> and share the drawing or sample through the <a href=\"https:\/\/koitorhardware.com\/de\/kontakt\/\" style=\"color:#0B5CAD;text-decoration:underline;\">project contact page<\/a>. A quotation can be more comparable when the weld convention, count, location, and acceptance questions are closed before pricing begins.<\/p>\n<h2>H\u00e4ufig gestellte Fragen<\/h2>\n<h3>What does a spot welding symbol show?<\/h3>\n<p>It communicates weld information according to the drawing\u2019s chosen convention and the symbol\u2019s relationship to the arrow, reference line, dimensions, notes, and other fields. The symbol does not by itself define every design, tolerance, process, or inspection requirement.<\/p>\n<h3>Is AWS A2.4 the same as ISO 2553?<\/h3>\n<p>No. They are separate symbol conventions. The buyer should identify the governing standard and edition for the project and avoid mixing interpretations from a different system.<\/p>\n<h3>Does the symbol decide how strong the weld must be?<\/h3>\n<p>Only when the drawing and applicable standard provide the required strength or dimension information. The design owner must state the requirement; production should not invent it from a symbol alone.<\/p>\n<h3>Does spot-weld count tell the supplier exactly where each weld goes?<\/h3>\n<p>Not necessarily. The drawing must make the joint, pattern, and location clear through dimensions, datums, details, or referenced specifications. A count without a defined layout may leave an important question unanswered.<\/p>\n<h3>Can a supplier use an example number from a symbol chart?<\/h3>\n<p>No. Chart values are illustrative. They help demonstrate notation but are not product requirements, tolerances, or approval values for a buyer\u2019s part.<\/p>\n<h3>Does a visible weld prove that a specified requirement passed?<\/h3>\n<p>Not by itself. A visual observation may be one part of an acceptance plan, but the required evidence depends on the design criteria and agreed inspection method.<\/p>\n<h3>What should I do if the drawing uses a spot symbol but no standard is named?<\/h3>\n<p>Request clarification from the responsible design owner before quotation or production. Record the selected convention and issue a controlled drawing update or written clarification tied to the revision.<\/p>\n<h3>Can an OEM factory choose the weld quantity or spacing?<\/h3>\n<p>The supplier can propose a change for engineering review, but should not substitute its own count or spacing for the buyer\u2019s design requirement without approval. Any approved change needs to be documented and controlled.<\/p>\n<h3>Arbeiten Sie mit Koitor Hardware zusammen<\/h3>\n<p>Share the controlled drawing, symbol standard, material and thickness notes, sample, and acceptance questions. Koitor can review the fabrication and sourcing scope and identify what needs design-owner clarification before an RFQ is finalized.<\/p>\n<section class=\"koitor-blog-cta\" style=\"margin:28px 0;padding:24px;border:1px solid #eeeeee;border-radius:10px;text-align:center;\">\n<h3 style=\"margin:0 0 12px;\">Close the Drawing Questions Before You Request a Weld Quote<\/h3>\n<p style=\"margin:0 0 18px;\">Send the drawing revision, weld-symbol convention, material details, and sample for a scoped discussion.<\/p>\n<div style=\"display:flex;flex-wrap:wrap;gap:12px;justify-content:center;\">\n    <a href=\"https:\/\/koitorhardware.com\/de\/kontakt\/\" style=\"display:inline-flex;align-items:center;justify-content:center;padding:13px 20px;border-radius:6px;text-decoration:none;font-weight:700;background:#FF5A1F;color:#ffffff;\">Kontaktieren Sie Koitor<\/a><br \/>\n    <a href=\"https:\/\/koitorhardware.com\/de\/oem-home-storage-hardware-manufacturer\/\" style=\"display:inline-flex;align-items:center;justify-content:center;padding:12px 20px;border:1px solid #FF5A1F;border-radius:6px;text-decoration:none;font-weight:700;color:#FF5A1F;background:#ffffff;\">Review OEM Scope<\/a>\n  <\/div>\n<div class=\"koitor-article-tags\" style=\"display:flex;flex-wrap:wrap;gap:8px;justify-content:center;margin-top:18px;\">\n    <span style=\"display:inline-flex;padding:6px 11px;border-radius:999px;background:#FFF3ED;color:#b83c12;font-size:13px;\">Fertigung<\/span><br \/>\n    <span style=\"display:inline-flex;padding:6px 11px;border-radius:999px;background:#FFF3ED;color:#b83c12;font-size:13px;\">Qualit\u00e4tskontrolle<\/span><br \/>\n    <span style=\"display:inline-flex;padding:6px 11px;border-radius:999px;background:#FFF3ED;color:#b83c12;font-size:13px;\">OEM-Produktentwicklung<\/span>\n  <\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Read a spot welding symbol by confirming the drawing standard, joint location, size, count, pitch, process notes, units, and acceptance criteria.<\/p>","protected":false},"author":1,"featured_media":8502,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[80],"tags":[418,75,37],"class_list":["post-8505","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-manufacturing-process","tag-manufacturing","tag-oem-product-development","tag-quality-control"],"_links":{"self":[{"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/posts\/8505","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/comments?post=8505"}],"version-history":[{"count":1,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/posts\/8505\/revisions"}],"predecessor-version":[{"id":8510,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/posts\/8505\/revisions\/8510"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/media\/8502"}],"wp:attachment":[{"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/media?parent=8505"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/categories?post=8505"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/koitorhardware.com\/de\/wp-json\/wp\/v2\/tags?post=8505"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}