{"id":9823,"date":"2026-11-23T02:52:15","date_gmt":"2026-11-23T02:52:15","guid":{"rendered":"https:\/\/koitorhardware.com\/?p=9823"},"modified":"2026-11-23T02:53:38","modified_gmt":"2026-11-23T02:53:38","slug":"coa-vs-coc-test-results-conformance","status":"publish","type":"post","link":"https:\/\/koitorhardware.com\/es\/coa-vs-coc-test-results-conformance\/","title":{"rendered":"CoA vs CoC: Separate Test Results from the Conformance Statement"},"content":{"rendered":"<p>CoA vs CoC compares two different kinds of supplier quality documents. A Certificate of Analysis (CoA) commonly reports analysis, inspection, or test results for an identified product or material; a Certificate of Conformance (CoC) commonly states that supplied goods meet identified requirements. The acronyms alone do not prove that a document applies to the delivered lot, that testing was independent, or that a finished assembly meets every buyer requirement. Before accepting either document, check the issuer, product or lot identity, specification revision, characteristics covered, actual results or statement, and limits of what the record establishes.<\/p>\n<h2>What Is a Certificate of Analysis?<\/h2>\n<p>A Certificate of Analysis is commonly used to record results associated with identified requirements. Depending on the issuer, product, and context, a CoA may show inspection or test parameters, acceptance criteria, measured or qualitative results, lot or batch references, approval details, and document traceability. The precise contents are not universal. One document might present quantitative values; another might summarize qualitative outcomes; a third might refer to a separate report or specification.<\/p>\n<p>Illumina&#8217;s Certificate of Analysis FAQ illustrates one issuer-specific format for its diagnostic products. It describes its CoA as tied to product release specifications and lists fields including product and lot identification, test conditions, parameters, requirements, qualitative or quantitative results, approval, and document references. That example shows why a buyer should look beyond the title and inspect the record&#8217;s actual fields. It does not establish a mandatory format for metal hardware or imply that all CoAs contain the same information.<\/p>\n<p>A CoA is useful only to the extent that the reported scope matches the buyer&#8217;s question. A certificate for a raw material may address properties of that material but not finished-product assembly, dimensions, packaging, or mounting performance. A report that describes one sample may not establish the characteristics of every unit in a production lot. The buyer should determine whether the record is for incoming material, a process sample, a component, or a finished product.<\/p>\n<p>Some records are called certificates even when they are closer to an inspection summary or supplier report. Conversely, a supplier may issue a separate inspection report that contains detailed results but is not titled a CoA. The document name does not replace review of its issuer, content, approval status, and traceability.<\/p>\n<h2>What Is a Certificate of Conformance?<\/h2>\n<p>A Certificate of Conformance (also called a Certificate of Conformity or, in some contexts, Certificate of Compliance) commonly states that identified goods or services conform to specified requirements. A CoC may identify the supplier, product, part number, lot, order, drawing revision, applicable requirements, signer, and date. The declaration is meaningful only when the underlying requirement and product scope are clear.<\/p>\n<p>The CoC may be a concise statement and may not include detailed measurement values. Some documents attach results or refer to inspection records; others do not. A supplier&#8217;s statement can support a buyer&#8217;s document review, but it should not be mistaken for an independent laboratory report or proof that every characteristic was measured unless the document and supporting evidence say so.<\/p>\n<p>The requirement matters. A conformance statement that refers only to a purchase order may not reveal which drawing revision or characteristics were considered. If the purchase order includes several documents or changes, the buyer should confirm which version controls. If the statement references a standard, specification, or customer drawing, identify the exact revision and applicability rather than assuming the name alone resolves the scope.<\/p>\n<p>A CoC also does not automatically establish regulatory compliance. \u201cConformance\u201d can refer to a buyer&#8217;s drawing, purchase specification, contractual requirement, internal inspection rule, or an applicable regulatory document. These are not interchangeable. The buyer should ask what the issuer is declaring against and whether the statement is within that issuer&#8217;s authority and actual knowledge.<\/p>\n<h2>How Are CoA and CoC Different?<\/h2>\n<p>At a high level, a CoA focuses on analysis, inspection, or test results; a CoC focuses on a statement that goods meet stated requirements. This is a common distinction, not a universal legal format. Some organizations use the terms differently, and a document may combine a declaration with results or reference separate evidence.<\/p>\n<div class=\"wp-block-table koitor-responsive-table\" style=\"max-width:100%;overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;overflow-wrap:anywhere;\">\n<thead>\n<tr>\n<th>Pregunta del comprador<\/th>\n<th>Certificate of Analysis (CoA)<\/th>\n<th>Certificate of Conformance (CoC)<\/th>\n<th>What to verify<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Main information need<\/td>\n<td>What was analyzed, inspected, or tested and what result was recorded?<\/td>\n<td>What requirement does the issuer state the goods meet?<\/td>\n<td>Actual document content and intended use<\/td>\n<\/tr>\n<tr>\n<td>Common detail<\/td>\n<td>Parameters, criteria, values or qualitative results, lot or sample identity<\/td>\n<td>Product or lot identity, requirement or revision, declaration, issuer and date<\/td>\n<td>Whether the characteristic and item match the order<\/td>\n<\/tr>\n<tr>\n<td>Evidence type<\/td>\n<td>Results may be included, with scope depending on the issuer<\/td>\n<td>A declaration may be present without detailed measured results<\/td>\n<td>Whether supporting reports are attached or referenced<\/td>\n<\/tr>\n<tr>\n<td>Typical limitation<\/td>\n<td>A result may cover only a sample, material, or specified test<\/td>\n<td>A statement may not show how each requirement was verified<\/td>\n<td>What the record does not establish<\/td>\n<\/tr>\n<tr>\n<td>Buyer follow-up<\/td>\n<td>Confirm method, conditions, result basis, sample and lot linkage<\/td>\n<td>Confirm requirement, revision, responsible signer and product scope<\/td>\n<td>Whether another inspection or document is needed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>SyncTronics, an electronics-component supplier, provides another manufacturer-side example describing a CoC as a conformance declaration and a CoA as a record of actual inspection or laboratory results. Its article illustrates one supplier&#8217;s explanation and examples; it is not a universal industry standard. The safer buyer practice is to interpret the specific document and agreement instead of relying on an acronym expansion.<\/p>\n<p>The CoA vs CoC choice should follow the evidence need. If the buyer needs to know whether a defined characteristic was measured and what value was recorded, a statement without results may not answer that question. If the buyer needs a supplier declaration against a controlled drawing or purchase specification, a result sheet alone may not contain the required declaration. A project can request both when the buyer&#8217;s defined process requires them, but no general rule says every shipment needs both.<\/p>\n<h2>How Can Buyers Check a Certificate Against the Delivered Product?<\/h2>\n<p>Start with identity and traceability. Does the record identify the supplier, product, part number, material, order, lot, sample, or shipment reference that matters? If a certificate covers a batch, compare its lot identifier with the purchase and shipping records. If it covers a sample, determine whether the sample was drawn from the production lot and how that link is documented.<\/p>\n<p>Next, check the requirement. Does the record cite the current drawing, purchase specification, or acceptance criteria? Is the revision clear? If a requirement changed after the document was issued, confirm whether the statement still applies. A document can be authentic and still be irrelevant to a newer revision or a different product variant.<\/p>\n<p>Then inspect the evidence content:<\/p>\n<ul>\n<li>What property, characteristic, or requirement is addressed?<\/li>\n<li>Is the result numeric, qualitative, a pass\/fail outcome, or only a declaration?<\/li>\n<li>Is the test or inspection method identified?<\/li>\n<li>Are conditions, sample quantity, and measurement units stated where relevant?<\/li>\n<li>Is the issuer identified, and is the approval date or signature clear?<\/li>\n<li>Are exceptions, exclusions, deviations, or unresolved items listed?<\/li>\n<li>Is there a referenced report that the buyer must request separately?<\/li>\n<\/ul>\n<p>Finally, define what the document does not prove. A raw-material CoA may not prove finished-item dimensions. A supplier CoC may not demonstrate independent testing. A test result from one specimen does not automatically establish every unit&#8217;s conformity. A certificate may not address a product&#8217;s entire life in service. The buyer should map each requirement to the evidence needed rather than treating a certificate as a universal quality guarantee.<\/p>\n<p>A receiving team can use a controlled document review table:<\/p>\n<div class=\"wp-block-table koitor-responsive-table\" style=\"max-width:100%;overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;overflow-wrap:anywhere;\">\n<thead>\n<tr>\n<th>Requisito<\/th>\n<th>Evidence requested<\/th>\n<th>Record received<\/th>\n<th>Identity \/ revision match<\/th>\n<th>Result or statement<\/th>\n<th>Open action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Material identity<\/td>\n<td>Supplier material record or defined analysis<\/td>\n<td>Document number and date<\/td>\n<td>Lot and grade match?<\/td>\n<td>What is stated or measured?<\/td>\n<td>Resolve missing traceability<\/td>\n<\/tr>\n<tr>\n<td>Critical dimension<\/td>\n<td>Inspection record against current drawing<\/td>\n<td>Sample or lot reference<\/td>\n<td>Drawing revision match?<\/td>\n<td>Value, units, and criterion<\/td>\n<td>Request missing method or result<\/td>\n<\/tr>\n<tr>\n<td>Finish appearance<\/td>\n<td>Approved sample\/specification and receiving check<\/td>\n<td>Inspection or conformance record<\/td>\n<td>Finish and product variant match?<\/td>\n<td>Observation or declaration<\/td>\n<td>Clarify excluded surfaces<\/td>\n<\/tr>\n<tr>\n<td>Packaging configuration<\/td>\n<td>Pack-out specification or shipment check<\/td>\n<td>Packing or inspection record<\/td>\n<td>SKU and carton reference match?<\/td>\n<td>Count or statement<\/td>\n<td>Reconcile discrepancy<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>This table is an example, not a mandated format. The buyer may need different fields for a particular product or contract. The key is to connect each requirement to an identifiable record and to assign an owner for any gap.<\/p>\n<h2>What Should a Hardware Buyer Request from a Supplier?<\/h2>\n<p>A buyer should describe the product and evidence need in practical terms instead of asking only, \u201cCan you provide a CoA?\u201d Identify whether the need concerns incoming metal material, a purchased component, a surface treatment, finished-product inspection, or an assembled item. Then specify the exact characteristic, requirement, lot or sample basis, and record fields the buyer expects.<\/p>\n<p>For example, if the buyer needs to review a metal grade, state which material and product stage are in scope. If the request concerns a finished rack&#8217;s key dimension, cite the controlled drawing revision and identify the dimension. If the request concerns finish appearance, identify the approved reference and surfaces. The supplier can then say which records exist, who issued them, and which characteristics they cover.<\/p>\n<p>Do not assume a supplier&#8217;s general quality statement means that an accredited laboratory tested the product. Ask whether the result comes from internal inspection, an external laboratory, a material supplier&#8217;s certificate, or another source. If accreditation or a particular test method is required, the buyer should state that requirement and verify the evidence directly. The word \u201ccertificate\u201d alone does not prove accreditation.<\/p>\n<p>A buyer should also clarify whether the requested record is required per lot, shipment, sample, or order. Frequency and sampling basis should follow the contract or quality plan; do not invent a universal per-unit rule. If a supplier offers a combined document, ask which section provides the declaration and which section provides actual results.<\/p>\n<h3>How should lot and sample coverage be evaluated?<\/h3>\n<p>A document&#8217;s link to a lot, batch, or sample is central to its usefulness. Ask how the tested item was selected, who identified it, and what the supplier means by a lot. The answer may be defined by a purchase specification, internal procedure, or material supplier&#8217;s traceability system. Do not assume that \u201clot\u201d has the same boundary across every supplier or product. The buyer&#8217;s record should show the identifier used and how it connects to the delivered items.<\/p>\n<p>If results were measured on a sample, verify the sampling plan or stated basis where the purchase requirements call for it. One result can support a defined sample decision, but it may not show every unit was individually inspected. If the buyer needs a result for each piece, that requirement must be explicit and technically appropriate; do not infer a per-unit test from a certificate title. If the document aggregates results, ask whether it reports an individual value, range, average, pass\/fail conclusion, or another statistic. Each format answers a different question.<\/p>\n<p>Also distinguish identity evidence from performance evidence. A material certificate may identify grade or chemistry for a supplied lot, while a product inspection report may record dimensions on selected finished units. Neither automatically verifies the mounting function, assembled load, coating durability, or packaging condition unless those items are within the documented scope and the method supports the conclusion. The buyer&#8217;s specification should connect each requirement to a suitable record, sample basis, or test.<\/p>\n<p>For a coa vs coc review, the practical issue is whether the document type and its contents satisfy the identified information need. A document called \u201canalysis certificate\u201d with no results may not answer a request for measured values. A \u201cconformance certificate\u201d that names no specification may not let the buyer determine what was declared. Ask the supplier to clarify the record or provide the related evidence rather than deciding by title alone.<\/p>\n<p>The buyer can set limits on acceptable document substitutions. For instance, a material supplier&#8217;s certificate may help support a material identity requirement but may not replace the buyer&#8217;s required finished-item inspection record. A CoC may state that the supplier considers an item conforming, but may not replace measured values if the buyer needs those values to review a characteristic. These distinctions should be in the purchase requirements before production or shipment whenever possible.<\/p>\n<figure class=\"wp-block-image size-large koitor-blog-image\" style=\"margin:32px 0;\">\n<img decoding=\"async\" src=\"https:\/\/koitorhardware.com\/wp-content\/uploads\/2026\/11\/k1909-process-web.webp\" alt=\"A buyer matches a supplier certificate to the product lot and controlled specification\" style=\"width:100%;max-width:960px;height:auto;display:block;margin:0 auto;border-radius:10px;\" \/><figcaption style=\"font-size:14px;color:#667085;text-align:center;margin-top:8px;\">Match the record to the product, lot, requirement, and revision under review.<\/figcaption><\/figure>\n<h2>What Common Certificate Review Mistakes Should Importers Avoid?<\/h2>\n<p>One mistake is accepting a document because the acronym looks familiar. Expand the abbreviation, read the actual statement, and confirm what the document covers. \u201cCoA\u201d and \u201cCoC\u201d can be used differently by different organizations, and a translation or supplier template may use an alternate title.<\/p>\n<p>Another mistake is treating a CoA as proof of all product quality. Analysis results may cover only stated properties and samples. They do not automatically prove appearance, dimensions, assembly, packaging, or field durability. Ask which attributes were assessed and what was outside the test scope.<\/p>\n<p>A third mistake is treating a CoC as a complete test report. A declaration may be based on inspection, production records, a supplier&#8217;s internal procedure, or another method. If the buyer needs measured data, request the relevant results and method. Do not infer unreported measurements from a signed statement.<\/p>\n<p>A fourth mistake is ignoring revision control. The certificate may reference a superseded drawing, outdated material specification, or old order. Verify the latest applicable revision and record any deviation. The broader distinction between <a href=\"https:\/\/koitorhardware.com\/es\/statistical-control-limits-specification-limits-difference\/\">statistical control limits and specification limits<\/a> is useful when reading process information, but it does not convert a certificate into a product acceptance decision.<\/p>\n<p>A fifth mistake is assuming a document title guarantees a particular issuer or independence. Check who issued it and whether a test came from an internal lab, material supplier, inspection firm, or independent laboratory. If a third-party inspection is required, define scope and timing before the order; this related guide explains steps when a <a href=\"https:\/\/koitorhardware.com\/es\/supplier-requests-change-third-party-inspection-booking\/\">supplier requests a change to a third-party inspection booking<\/a>. It does not determine the validity of a separate CoA or CoC.<\/p>\n<figure class=\"wp-block-image size-large koitor-blog-image\" style=\"margin:32px 0;\">\n<img decoding=\"async\" src=\"https:\/\/koitorhardware.com\/wp-content\/uploads\/2026\/11\/k1909-checklist-web.webp\" alt=\"A buyer checklist links a certificate to the product lot, specification revision, issuer, and open evidence\" style=\"width:100%;max-width:960px;height:auto;display:block;margin:0 auto;border-radius:10px;\" \/><figcaption style=\"font-size:14px;color:#667085;text-align:center;margin-top:8px;\">Check identity, revision, issuer, and record scope before closing the review.<\/figcaption><\/figure>\n<p>When a supplier cannot provide the requested document, ask what record is available and why it differs from the requirement. The supplier may have an internal inspection record, an upstream material certificate, a third-party report, a signed declaration, or no relevant record. These options are not automatically equivalent. Compare the alternative record with the exact requirement and ask the designated quality owner to approve or reject the substitution. Keep any waiver or exception in writing and tied to the order or lot so it is not applied to future shipments by accident.<\/p>\n<p>If a buyer requires a third-party inspection, the inspection scope should identify the product, sample basis, characteristics, timing, and acceptance criteria. The fact that an inspection company attended does not prove it reviewed every requirement, and the presence of a CoA does not prove a third party issued it. Link the report, certificate, and purchase requirement in the document set while preserving which record supports which conclusion. This avoids treating the documents as interchangeable just because they refer to the same order.<\/p>\n<p>Finally, do not let a missing document become an assumed pass. Record what was requested, what arrived, what matches, and what remains open. Escalate the issue to the designated quality or purchasing owner under the agreed acceptance procedure. Keep the original records and the clarification trail so later teams can see how the decision was made.<\/p>\n<p>If a buyer&#8217;s terminology conflicts with the supplier&#8217;s terminology, define the deliverable by content rather than insisting on an abbreviation. The request can name the required product and lot identifiers, the specification revision, results or declaration needed, and supporting method or approval fields. The supplier can confirm which existing document satisfies that content and where any gap remains. This reduces translation ambiguity without changing the requirement. The buyer should approve a substitute record only through the applicable purchasing or quality process, especially when the contract specifies a particular document.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>Must every CoA contain numerical test results?<\/h3>\n<p>No universal format follows from the name. A CoA may contain quantitative results, qualitative results, or other analysis information depending on its issuer and scope. Check the actual document and buyer requirement.<\/p>\n<h3>Does a CoC prove independent laboratory testing?<\/h3>\n<p>No. A conformance statement does not by itself identify independent testing. The issuer and supporting evidence must be reviewed.<\/p>\n<h3>Can a CoC include test results?<\/h3>\n<p>Yes. A supplier may include results or attach a report, but the document&#8217;s exact contents and applicability should be confirmed.<\/p>\n<h3>Can a CoA apply to an entire production lot?<\/h3>\n<p>It can be lot-linked if the issuer&#8217;s record and sampling basis support that scope. Verify the lot identity and how the sample or results relate to the delivered items.<\/p>\n<h3>Are CoA and CoC documents the same as RoHS or REACH declarations?<\/h3>\n<p>No. The terms may appear together in supplier documentation, but they address different information needs. Regulatory scope and applicability must be checked separately under current rules.<\/p>\n<h3>Should an importer always request both documents?<\/h3>\n<p>No universal rule requires both for every product or shipment. Define which requirements and evidence the buyer needs, then request the applicable record under the contract and quality plan.<\/p>\n<h3>Sources and Scope<\/h3>\n<ul>\n<li>Illumina, <a href=\"https:\/\/support.illumina.com\/content\/dam\/illumina-support\/documents\/documentation\/chemistry_documentation\/dx\/faq-cofa.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Certificate of Analysis FAQ<\/a> \u2014 used as an issuer-specific example of a CoA&#8217;s possible fields and lot traceability, and its own explanation of CoA versus CoC. Its diagnostic product context is not generalized into hardware requirements.<\/li>\n<li>SyncTronics Technology, <a href=\"https:\/\/en.synctronics.com.tw\/what-are-coc-and-coa.htm\" rel=\"nofollow noopener\" target=\"_blank\">What Are CoC and CoA?<\/a> \u2014 used as a manufacturing supplier&#8217;s explanation and example of document purposes. Its sector-specific claims, regulatory references, and \u201ccommonly requested\u201d language are not treated as universal rules.<\/li>\n<li>This article is general buyer education. It does not certify a product, establish accreditation, define legal document requirements, replace a quality agreement, or claim Koitor operates a testing laboratory.<\/li>\n<\/ul>\n<section class=\"koitor-blog-cta\" style=\"margin-top:36px;padding:28px;border:1px solid #D0D5DD;border-radius:16px;background:#F8FAFC;\">\n<h3 style=\"margin-top:0;margin-bottom:12px;font-size:28px;line-height:1.25;color:#101828;\">Clarifying Quality Records for a Hardware Order?<\/h3>\n<p style=\"font-size:16px;line-height:1.7;margin-bottom:20px;color:#344054;\">Share the controlled drawing or specification, product or lot reference, and the exact evidence needed. Koitor can discuss approved custom metal hardware scope and available project records without implying laboratory certification.<\/p>\n<div style=\"display:flex;gap:12px;flex-wrap:wrap;align-items:center;margin-bottom:24px;\">\n    <a href=\"https:\/\/koitorhardware.com\/es\/contacto\/\" style=\"display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:0 22px;border-radius:8px;background:#FF5A1F;color:#ffffff;font-weight:700;text-decoration:none;line-height:1;\">Send Your Project Question<\/a><br \/>\n    <a href=\"https:\/\/koitorhardware.com\/es\/fabricante-de-herrajes-para-el-hogar-de-marca-propia\/\" style=\"display:inline-flex;align-items:center;justify-content:center;min-height:48px;padding:0 22px;border-radius:8px;border:1px solid #FF5A1F;color:#FF5A1F;background:#ffffff;font-weight:700;text-decoration:none;line-height:1;\">Review OEM Scope<\/a>\n  <\/div>\n<div class=\"koitor-article-tags\" style=\"margin-top:24px;padding-top:18px;border-top:1px solid #E5E7EB;display:flex;align-items:center;gap:8px;flex-wrap:wrap;\">\n    <span style=\"font-size:14px;font-weight:700;color:#344054;margin-right:4px;\">Etiquetas:<\/span><br \/>\n    <span style=\"display:inline-flex;align-items:center;justify-content:center;padding:6px 12px;border-radius:999px;background:#FFF3ED;color:#FF5A1F;font-size:13px;font-weight:600;line-height:1.2;\">Control de calidad<\/span><br \/>\n    <span style=\"display:inline-flex;align-items:center;justify-content:center;padding:6px 12px;border-radius:999px;background:#FFF3ED;color:#FF5A1F;font-size:13px;font-weight:600;line-height:1.2;\">Gu\u00eda de compra para importadores<\/span><br \/>\n    <span style=\"display:inline-flex;align-items:center;justify-content:center;padding:6px 12px;border-radius:999px;background:#FFF3ED;color:#FF5A1F;font-size:13px;font-weight:600;line-height:1.2;\">Accesorios met\u00e1licos para almacenamiento<\/span>\n  <\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>A practical guide to distinguishing a Certificate of Analysis from a Certificate of Conformance and matching each document to a buyer&#8217;s evidence need.<\/p>","protected":false},"author":1,"featured_media":9822,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[16],"tags":[40,48,37],"class_list":["post-9823","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-quality-control-articles","tag-importer-buying-guide","tag-metal-storage-hardware","tag-quality-control"],"_links":{"self":[{"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/posts\/9823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/comments?post=9823"}],"version-history":[{"count":1,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/posts\/9823\/revisions"}],"predecessor-version":[{"id":9824,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/posts\/9823\/revisions\/9824"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/media\/9822"}],"wp:attachment":[{"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/media?parent=9823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/categories?post=9823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/koitorhardware.com\/es\/wp-json\/wp\/v2\/tags?post=9823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}