A rivet size chart is useful only when its rivet family, source and column definitions stay attached to the numbers. For common blind rivets, a chart may show a body-diameter code, a nominal diameter, a body-length or maximum-length field, and a separate grip interval. Those fields answer different questions. The pulling mandrel is not the body diameter; a nominal body length is not automatically the sheet-stack range; and a head diameter is not the body diameter.
For a compact reference, one supplier’s guide maps codes 3, 4, 5, 6 and 8 to nominal body diameters of 3/32, 1/8, 5/32, 3/16 and 1/4 inch, respectively. It gives approximate trade-size metric labels of 2.4, 3.2, 4.0, 4.8 and 6.4 mm. These are that supplier’s named convention, not a universal rivet-numbering standard or exact mathematical conversions. A separate catalog comparison shows why the exact row matters: two Byler chart entries with the same 44 suffix and the same listed L(max) of .400 inch have different minimum grip values because they have different head families. A hypothetical .150-inch stack falls inside one listed interval and outside the other. That arithmetic narrows a chart lookup; it does not approve a fastener, joint or installation.
What does a rivet size chart describe?
The phrase “rivet size” can refer to several dimensions. A useful chart makes those dimensions distinct rather than compressing them into a single label. Before you compare two rows, check what type of rivet the chart covers, how the maker names the part, what units are shown, and how each column is defined.
This article focuses on interpreting published blind-rivet references for ordinary sheet-metal hardware discussions. It does not select structural, aerospace, aircraft, garment, leather, safety-critical or other engineered fasteners. A product’s exact drawing, the fastener maker’s current data and the responsible engineer’s requirements govern any actual selection. A chart can help you understand a catalog row; it cannot replace those documents.
A blind rivet typically has a tubular body and a mandrel that is pulled during setting. The body is the part that remains in the joined materials, while the mandrel is the pulling element. Therefore, a diameter entry for the body should not be confused with the mandrel diameter or with the head’s outside diameter. Similarly, body length and grip range are not synonyms. The former is a length dimension defined by a particular catalog; the latter describes a material-thickness interval for a specific rivet family and setting system.
A chart may also show a head style, material combination, finish, part number, drill recommendation, setting information or packaging unit. Those are not guaranteed to appear in every chart. A missing column is not permission to infer its value from a similar-looking part. If a field is essential to the buying decision and the chart does not define it, the correct next step is to find the exact maker’s specification or request it from the supplier.
What is the difference between rivet body diameter and the size code?
Some catalogs use a short code as part of the rivet designation. The code may correspond to a nominal body diameter within that manufacturer’s or supplier’s product family. The mapping must be read with the source’s own definitions; it should not be treated as an international code that every rivet brand follows.
For example, the Allfasteners rivet size guide identifies five common body-diameter code pairings: code 3 with 3/32 inch, code 4 with 1/8 inch, code 5 with 5/32 inch, code 6 with 3/16 inch, and code 8 with 1/4 inch. The guide also displays metric trade labels of 2.4, 3.2, 4.0, 4.8 and 6.4 mm. Keep those values together as a named supplier reference. Do not present them as a universal code table.
The metric labels are rounded commercial equivalents, not exact conversions of the inch fractions. For example, 1/8 inch converts mathematically to 3.175 mm; a supplier may show 3.2 mm as a practical nominal label. This does not mean that every nominal 3.2 mm rivet is interchangeable with every 1/8-inch rivet. The exact part family, body construction, material, head, manufacturing tolerance and specification still matter.
Do not decode a complete catalog number by looking at only one digit or suffix. A letter may identify the head family, material, body type, mandrel or a product-series variant. A number may identify a body size, length, grip or a combination specific to that catalog. The part number is a lookup key, not a universal formula. Read the maker’s key or row heading before assigning meaning to any character.
A buyer should preserve the full part number and description when comparing quotations. If one supplier quotes a “4” and another quotes “1/8,” they may be pointing to similar nominal diameter labels, but that similarity alone does not establish equivalent construction or fit. Ask each supplier to state the complete item identifier and the actual dimensions and grip range required by the design. If a substitute is proposed, document who approved the substitution and against which technical requirements.
How should you read the body-length field?
A length value can be misleading if you do not know where its measurement endpoints lie. Some charts define a maximum body length using a drawing. Other catalogs use a diameter-by-length notation such as D × L. Head style can affect the drawing convention. One source may place the body-length arrow below a protruding head; another may include a countersunk head in the displayed length. These conventions are specific to the chart that illustrates them.
The POP/Byler chart library provides an example of why the drawing matters. In the linked POP aluminum and steel rivet chart, the L(max) dimension is shown relative to the dome or large-flange head, while the countersunk drawing uses a different length convention that includes the head in L. This is a chart-specific illustration. It is not a universal rule for measuring every brand or rivet head.
A separate historical example appears in GESIPA’s 2021/22 catalog: a CAP 4 × 11 entry, part 1433433, identifies a 4 mm body diameter and an 11 mm body length, while its distinct grip entry is 5.0–6.5 mm. The entry is useful for understanding how one catalog separates D, L and grip. It is not evidence of current stock, current availability or a universal specification.
The mandrel projection is not automatically part of the body-length value. If you are inspecting a loose sample, do not measure from the end of the mandrel and call that the rivet length unless the relevant manufacturer’s definition explicitly says to do so. A sample measurement can help identify a mismatch or ask a better supplier question, but the maker’s drawing determines which endpoints and tolerances apply.
When two sources use the same word “length,” compare the diagrams and definitions before comparing their values. If a drawing is absent, label the convention as unconfirmed. Do not normalize the entries into one table by assuming that all catalogs measure the same endpoints. A clear supplier clarification is more useful than a false cross-brand conversion.
What is grip range, and why is it separate?
Grip range describes the thickness interval for which a specified rivet configuration is intended to be used, according to its maker’s data. A chart row may show a minimum and a maximum grip. Both ends matter. A stack that is above the minimum but beyond the maximum does not satisfy the printed interval, and a stack below the minimum cannot be treated as acceptable simply because the rivet body looks long enough.
Grip belongs to the exact model and family. It can vary with body length, head form, material combination, body design and manufacturer’s setting conditions. The range cannot be reconstructed safely from a suffix, a nominal diameter or a maximum-length field alone. Preserve the complete part number and the exact chart row whenever you record a grip interval.
Here is a source-specific comparison from the POP/Byler size chart. The AD44BS dome-head row and the AD44BSLF large-flange row both show a 1/8-inch diameter and an L(max) of .400 inch. Their listed grip intervals differ: .188–.250 inch for the dome-head row and .126–.250 inch for the large-flange row. The shared 44 suffix and maximum-length value do not make the minimum grip identical. The head-family identifier and row remain essential.
For a simple arithmetic illustration, suppose a buyer’s hypothetical joined stack is .150 inch thick. That number lies within the stated .126–.250 interval but below the .188 minimum of the other row. This is only an interval comparison based on the two named chart entries. It is not an instruction to substitute the large-flange rivet, an assessment of joint strength, or approval that either rivet suits a real application. The actual part identity, material, hole, access, setting equipment and design requirements still need review.
The practical lesson is to compare the measured or specified stack with both limits in the exact row, not with an approximate “size” remembered from another catalog. If the stack changes because a washer, coating, gasket or revised sheet is added, review the selected part again. Do not extend a published interval by rounding or by assuming that a longer body automatically solves every mismatch.
Grip qualification for a particular joint is a separate engineering decision. Keep this guide focused on chart reading: it explains what the fields mean and why the exact maker row must remain attached to the values. Use the current product drawing and supplier documentation for application-specific selection.
How does a metric D × L entry differ from a code-and-grip entry?
A D × L notation often places nominal diameter and body length together. That compact expression does not necessarily include the grip range. It is also different from a supplier’s size code. The context and catalog key tell you which value is which.
The GESIPA 2021/22 catalog’s CAP 4 × 11 example lists a 4 mm diameter and an 11 mm body length, alongside a separate 5.0–6.5 mm grip entry. This shows why one short description can contain different kinds of measurements. Reading “4 × 11” as a grip interval would be a category error. Treat it as a source-specific D × L notation and confirm the separate grip field in the same catalog row.
Another supplier’s A-S4-10 example illustrates a different convention. In the Allfasteners guide, S4 points to a 3.2 mm nominal body diameter under that supplier’s code mapping, while the example is associated with a 12.7–15.9 mm grip range. It does not mean a 4 mm diameter by 10 mm length. The notation must be read using the specific key and row; it cannot be safely parsed by treating each digit as a universal dimension.
Keep mixed-unit examples separated. An inch chart entry should stay in inches when you cite it, and a metric catalog entry should stay in metric units. If a project requires conversion, show the original dimension and the converted value side by side, identify the conversion and rounding method, and have the responsible technical reviewer approve the drawing value. Do not change a catalog value silently or combine the inch diameter from one manufacturer with the grip interval from another.
How should a buyer compare two rows without confusing them?
| Named catalog row | Head style | Body diameter | L(max) | Listed grip interval |
|---|---|---|---|---|
| AD44BS | Dome | 1/8 in | .400 in | .188–.250 in |
| AD44BSLF | Large flange | 1/8 in | .400 in | .126–.250 in |
These two named rows come from the POP Rivet Tooling chart library and its linked Byler chart. They illustrate a source-specific difference, not universal equivalence or approval.
Use a structured comparison rather than a quick scan of the numbers. Start by writing down the source or manufacturer, catalog or document title, revision or date when supplied, full part number, head type and material description. If two rows do not identify comparable product families, stop before comparing their dimensions as if they describe equivalent parts.
Next, label each field in plain language: body diameter, body-length definition, grip minimum and maximum, head diameter if shown, and any other design-specific field that matters. Keep the original column headings visible. A cropped screenshot that loses the heading or source can turn an accurate number into an unsafe guess. Record the source page or row reference beside any value you copy into a specification review.
Then compare units and rounding. Do not translate a rounded trade-size label into a precision tolerance. A table’s nominal diameter does not automatically give the finished hole size, permissible variation, positional requirement or coating allowance. Those belong to the controlled drawing or separately agreed inspection criteria. Likewise, a chart’s suggested drill value, if present, remains source-specific and must not be copied from a different family.
After that, compare the exact grip range with the documented material stack. Keep the minimum and maximum visible. Do not use the midpoint as a substitute, and do not compare the stack to a maximum-body-length field as if those were the same dimension. If the stack includes a coating, pad, washer, adhesive layer or extra plate, define whether that layer belongs in the dimension being compared. The responsible designer or engineer determines the required stack and approved part.
Finally, preserve a decision trail: the selected catalog row, the drawing revision, reviewer, date and any open question. If a supplier offers an alternative, request the full manufacturer identifier and a comparable data sheet. A similar code, nominal diameter or maximum length does not prove equivalence. When the information is incomplete, mark the comparison as pending instead of choosing a row based on visual similarity.
What does a chart not prove?
A size chart is not a joint-design calculation. It does not establish the load capacity, fatigue behavior, vibration resistance, corrosion life, installation quality, service life or suitability of a rivet for a specific product. Those questions depend on the complete fastener, joined materials, hole preparation, edge distance, geometry, access, installation tool and qualification evidence. The source set used for the examples above does not establish those outcomes.
A chart does not prove that two suppliers’ rivets are interchangeable. Matching nominal diameter and apparent length leaves material, mandrel behavior, head style, grip, setting requirements and maker tolerances unresolved. A buyer considering a substitute should route it through the applicable drawing and approval process rather than assume that a close-looking catalog row is equivalent.
A chart also does not guarantee current availability. The GESIPA entry discussed above comes from a 2021/22 catalog and is used only to illustrate notation. It must not be used as an inventory statement, price quotation or current product recommendation. Confirm current product documentation with the manufacturer or authorized supplier.
Nor does a chart validate a hole simply because a rivet passed through it or was successfully set in one sample. A sample check is an observation of that sample under its particular conditions. It does not become a production tolerance or performance result unless the responsible quality plan defines what was measured, how it was measured and what acceptance criteria apply.
For a hardware sourcing project, keep the chart in its proper role: a reference for understanding the supplier’s dimensional labels. Use the controlled product drawing and current component documentation for actual specifications, and keep any unresolved selection or performance question visible to the responsible buyer, engineer or quality reviewer.
A buyer’s quick chart-reading checklist
Before copying a rivet value into an RFQ or drawing review, answer the following questions:
- Does the chart cover the correct rivet family and application category?
- Is the exact source, catalog title or manufacturer visible?
- Do you have the complete part number and head style rather than only a suffix?
- Is the listed diameter the body diameter, and is the code defined by this source?
- Is the displayed length a maximum body length, a D × L notation, or another source-specific field?
- Does the drawing show where the length endpoints are measured?
- Are minimum and maximum grip values both shown for the exact part?
- Are all values kept in one unit system, without silent rounding?
- Is the stack thickness defined on the controlled drawing?
- Are hole, material, finish, setting and qualification requirements handled by their own current documentation?
- Does the record show which chart row was reviewed and who approved the actual design choice?
If a question cannot be answered from the source, keep it open. Ask the supplier or manufacturer for the applicable drawing or clarification. Do not fill a blank by borrowing a value from another rivet family.


A useful rivet size chart comparison keeps the maker, full part number, body dimensions and both grip limits in one view.
Häufig gestellte Fragen
Is rivet code 4 always a 1/8-inch body?
No. The Allfasteners guide uses code 4 for 1/8 inch within its own named convention. Treat that pairing as source-specific. Check the exact supplier or manufacturer’s code key and full item number before applying it to another family.
Does 4 × 11 mean a 4–11 mm grip range?
Not in the cited GESIPA example. Its 2021/22 catalog uses CAP 4 × 11 for a 4 mm diameter and 11 mm body length, with a separate 5.0–6.5 mm grip entry. Check the notation key and row headings in the exact catalog.
Is rivet length the same as grip range?
No. A catalog’s length field and its grip interval answer different questions. The maker’s drawing defines the length endpoints; the grip range identifies the specified stack interval for that model.
If two rivets share the same code suffix, can I use the same grip range?
Do not assume so. In the named POP/Byler examples, AD44BS and AD44BSLF share a 44 suffix and .400-inch L(max), while the listed minimum grip values differ. Read the complete part row.
Can a size chart tell me which rivet is strong enough?
Not by itself. The examples here explain dimensional notation and chart fields; they do not provide a joint-strength calculation or application approval. Use the design requirements and current manufacturer data for the intended application.
Does a metric label equal an exact inch conversion?
Not necessarily. Supplier metric labels may be rounded nominal trade sizes. Preserve the source value and units, and document any conversion separately rather than treating the labels as exact interchangeable dimensions.
Can I use the longest body length when my stack is outside the grip range?
A longer-looking body does not by itself establish suitability. Review the exact part’s published grip limits and current technical information; do not infer a new interval from another row.
Sources and limits
The numeric code examples are attributed to the Allfasteners rivet size guide. Its low-code grip table contains apparent inch-fraction transcription issues, so this article does not reproduce that table, its drill recommendations or its strength and corrosion marketing. The two named .400-inch L(max) comparisons come from the POP Rivet Tooling chart library and its linked Byler chart; they are catalog examples only. The D × L notation example is limited to the CAP 4 × 11 entry on printed page 43 of the GESIPA 2021/22 catalog. It is historical notation evidence, not a current stock or specification claim. Source images and tables are not reproduced.
For a bathroom or home-storage hardware drawing, keep purchased-component details, material stack, hole requirements and review responsibility explicit. Koitor can discuss the supported OEM scope for custom metal bathroom and home-storage hardware; this does not imply that Koitor manufactures rivets or certifies a riveted joint. Share the actual drawing or sample requirements for a scope discussion.