An install sheet can only explain how to install a flush bolt once it names the bolt family, the edge condition of the inactive leaf and the template and strikes the maker documents. A flush bolt sits in the edge of the inactive leaf of a pair of doors and shoots a bolt up into the head frame and down into the floor. Its job is to hold that leaf fixed so the active leaf has something to close against.
Problems show up quickly when the sheet is vague. The bolt is too short to reach the head strike. The mortise is cut for a square edge on a rebated door. The floor strike sits off the bolt line. A surface bolt is fitted where a flush bolt was specified. Each of these is a fit question that the sheet can settle before anyone cuts the door.
This guide is for importers, distributors and private-label teams selling door hardware for pairs of doors, including flush bolts and their strikes. Koitor Hardware is a family-owned China OEM manufacturer of custom metal bathroom and home storage hardware. The guide covers the install sheet. It makes no fire-rating, egress-code or security claim.
Latch types such as sliding, cam, draw and compression latches are covered in the live types of latches guide. Kick plates and door stops have their own pages: door kick plate sizing and mounting y floor door stop height and contact checks. This page covers flush bolts on the inactive leaf.
What does how to install a flush bolt depend on first?
It depends on the bolt family, the inactive leaf edge condition and the maker’s documented template and strikes. The family decides how the bolt operates and what it needs from the door. The edge condition decides how the mortise is cut. The template and strikes decide where everything goes.
Manual flush bolts are operated by a lever or slide on the door edge. The user throws the bolt up or down by hand. They are the simplest family and common on residential French doors and storage cupboards with pairs of doors.
Automatic flush bolts project automatically when the active leaf closes against a trigger, and retract when the active leaf opens. They are used where both leaves must open easily. They need an active-leaf trigger position and often a coordinator to close the leaves in the right order.
Constant-latching or self-latching flush bolts are similar to automatic bolts but stay projected and latch when the inactive leaf closes. They are used in specific commercial applications. Their installation follows detailed maker templates.
Surface-mounted slide bolts are a different product. They mount on the face of the door rather than in the edge. They are sometimes substituted for flush bolts, but they are not the same thing, and a flush bolt sheet should not include them.
For a brand, the question is what the listing and sheet can say. A manual flush bolt for residential French doors is a simple product. Automatic and self-latching bolts for commercial pairs are part of a door assembly with rules that depend on the building. The sheet should match the product and avoid code claims.
Which flush bolt family and leaf edge are on the job?
Identification has two parts: the bolt family from the packing list and drawing, and the edge of the inactive leaf from the door itself. Both must be confirmed before any cutting.
Manual lever bolts
A manual bolt has a lever or slide set into a face plate on the door edge. The bolt rod runs inside the door to the top or bottom. Lengths vary, and some come with extension rods. The sheet should name the bolt length and any extension supplied.
Automatic and self-latching bolts
These have a trigger or plunger that the active leaf presses, and a mechanism inside the door edge. They are longer and more complex. The sheet should name the model and refer to the maker’s full template, which usually includes the active leaf.
Square-edge leaves
A square edge is flat. The bolt face plate sits flush in a mortise cut straight into the edge. This is the simplest case and the one most templates assume.
Rebated and astragal edges
Many pairs of doors have rebated edges that overlap, or an astragal strip that covers the gap. The flush bolt must suit that edge. Some makers offer rebated face plates or kits. Fitting a square-edge bolt to a rebated edge leaves it standing proud or misaligned.
Door construction
Wood doors are mortised with a router or chisel. Hollow-metal doors often have factory preparation for flush bolts. Aluminum storefront doors use different hardware altogether. The sheet should say which constructions the packed bolt is designed for and exclude the rest.
Why the inactive leaf needs a fixed point
In a pair of doors, the active leaf usually carries the lockset and latches into the inactive leaf, not into the frame. If the inactive leaf is free, the active leaf has nothing solid to latch against, and the pair rattles or blows open. The flush bolts give the inactive leaf a fixed point at the head and floor, which is why their reach into the strikes matters so much.
That also explains why a pair with only a bottom bolt may feel loose at the top, and why warped leaves can stop bolts reaching their strikes. The sheet can explain this in a sentence, so installers understand why the strike positions must be marked with the door closed.
Cupboards and storage pairs
Pairs of cupboard doors, wardrobe doors and storage cabinet doors often use small flush bolts or barrel bolts on the inactive door. These are lighter products and the strikes are usually in the cabinet frame or shelf rather than a building floor. The sheet for cabinet flush bolts should say that, and should not use building-door language that does not apply.
What does the documented template and strike preparation involve?
The template is the maker’s drawing of the mortise, the face plate and the bolt positions. It is the single most important document for a flush bolt install. The sheet should tell the installer to use it and not to work from measurements taken from another bolt.
Edge mortise
The template shows the size and depth of the mortise for the bolt body and the face plate. The installer marks it on the door edge and cuts it to the template. Depths and sizes come from the template; the install sheet should not print its own.
Bolt rod channel
For longer bolts, a channel or bore runs from the mortise to the top or bottom of the door. The template shows its position. On hollow-metal doors, this is usually factory prepared.
Head strike
The head strike is fitted in the head frame above the bolt. Its position is found by projecting the bolt with the door closed and marking where it meets the frame. The strike is then mortised or fitted as the maker documents.
Floor strike and dust-proof strikes
The floor strike receives the bottom bolt. Some are simple plates; others are dust-proof strikes with a spring-loaded plunger that closes the hole when the bolt is withdrawn, keeping dirt out. The strike position is marked with the bolt projected and the door closed. The floor finish and any threshold affect the bolt length needed.
Bolt length to head and floor
The bolt must reach far enough into each strike to hold. The maker’s template and bolt length chart show what is needed for different door heights and undercut. The sheet should tell the installer to check bolt reach before cutting strikes.

Coordinating with the active leaf hardware
Flush bolts work together with the lockset, the strike on the active leaf and sometimes a door closer and coordinator. Automatic bolts in particular depend on the active leaf closing in the right order. The sheet should tell the installer to confirm the full hardware schedule for the pair before cutting, and to follow the maker’s sequence for any coordinated hardware.
On residential French doors, the active leaf’s latch usually engages a strike on the inactive leaf edge. That strike and the flush bolt face plate may compete for space on the same edge. The template should show both, and the installer should check that they do not overlap.
Finishes and matching hardware
Flush bolt face plates are visible on the door edge when the active leaf is open. Buyers usually want them to match the lockset and hinges. The listing and sheet should show the finish with a photo and the maker’s finish code, so the bolt can be matched to the rest of the hardware.
Weather and exterior pairs
Exterior French doors and patio pairs expose the bottom bolt and floor strike to water and grit. Dust-proof strikes help keep the floor hole clear. Finish choice affects corrosion. The sheet can mention these points and should follow the maker’s guidance on exterior use rather than claim weather resistance.
What should a flush bolt install sheet list?
The install section is a short set of fields followed by the template-based sequence. The table is a template for the sheet. It has no mortise depths or bolt lengths, because those belong to the maker’s template.
| Campo | What to write | Source |
|---|---|---|
| Bolt family | Manual lever, automatic, or self-latching, with model | Packing list and maker drawing |
| Bolt length and extensions | Body length and any extension rods supplied | Maker data |
| Leaf edge | Square, rebated, or astragal, with face plate type | Door details and maker data |
| Door construction | Wood, hollow metal, or other, as the bolt is designed for | Maker data |
| Template | The maker’s template reference | Maker template |
| Head strike | Strike type and fixing | Maker data |
| Floor strike | Plain or dust-proof strike, and floor type | Maker data |
| Exclusions | Fire-rated pairs, egress-regulated doors, storefront glass rails, surface bolts | Brand policy |
A typical sequence
A typical sequence for a manual bolt on a wood door runs like this. Confirm the bolt family and edge. Mark the template on the inactive leaf edge. Cut the mortise and any rod channel to the template. Fit the bolt and face plate. Hang the door, close it, project the bolt, mark the head and floor strike positions, fit the strikes, and test.
The sheet should copy the maker’s version of that sequence, including any specific order for automatic bolts and coordinators.
Testing the installation
Test with both leaves closed. Throw the bolts and check that they enter the strikes fully and smoothly. Open the active leaf and check that the inactive leaf stays fixed. For automatic bolts, check that the bolts project and retract with the active leaf as designed.
Adjustment
Many flush bolts allow small adjustment of bolt projection. Strikes may have slotted holes for alignment. The sheet should explain the adjustments the maker provides and not suggest filing or bending parts.
Tools for a wood door installation
Wood door installations usually need a marking gauge or the maker’s template, a router with the right cutter or chisels, a drill for the rod channel and strike holes, and screwdrivers. The sheet should list the tools the maker names and recommend eye protection and dust control when routing. It should not give router speeds or cutter sizes beyond the template.
Pre-hung and factory-prepared doors
Many commercial doors and some residential pairs arrive with factory preparation for flush bolts. In that case, the installer fits the bolt to the existing mortise and does not cut. The sheet should tell the installer to check for factory preparation first and to match the bolt model to it.
Thresholds, floor finishes and undercut
The floor strike sits in the floor or in a threshold. Carpets, tiles and stone change the floor level, and a threshold may need a hole for the bolt. The sheet should tell the installer to plan the floor strike with the final floor finish in place, because a strike fitted before the floor is finished may end up too low or covered.
Which doors and claims must the sheet exclude?
Flush bolts are used on many kinds of door pairs, some of which are covered by fire and life safety rules. The sheet should exclude those cases and avoid claims about them.
Fire-rated pairs
Fire-rated pairs of doors use hardware tested and listed for that purpose, installed as part of a labeled assembly. In the United States, fire doors are covered by NFPA 80. A general flush bolt sheet should exclude fire-rated pairs and refer installers to the door assembly supplier.
Egress and life safety
On doors that serve as exits, the hardware on the inactive leaf may need to allow it to open without special knowledge or effort, depending on the building and its use. Life safety codes such as NFPA 101 address this. The sheet should not claim that a flush bolt is suitable for any egress door and should refer installers to the building owner.
Security claims
A flush bolt holds the inactive leaf in place, but its resistance to forced entry depends on the whole door, frame and strike assembly. The sheet should not claim security performance or grades unless the product has been tested and certified.
Storefront glass rails and surface bolts
Aluminum storefront doors with narrow stiles and glass rails use different hardware and rebuild procedures. Surface-mounted slide bolts are a different product. The flush bolt sheet should exclude both.
Replacing an existing flush bolt
Many jobs are replacements rather than new installs. The old mortise and strikes may not match a new bolt from a different maker. The sheet should tell the installer to compare the old bolt with the new template before removing anything: face plate size, mortise depth, bolt rod length and strike type. If they differ, the installer may need to fill and recut, which is a carpentry task.
For buyers, the easiest replacement is a bolt from the same maker and model, or one the maker lists as a direct replacement. Listings that state face plate dimensions and bolt type help buyers check before ordering.
Record keeping for commercial projects
On commercial projects, the hardware schedule lists each door, its hardware and its finish. Flush bolts should appear in that schedule with their model and strike type. Keeping the install sheet with the schedule helps maintenance teams replace parts later without guessing.
What must a flush bolt install sheet not print?
Check the sheet against this list before release.
- Fire-rating or fire-door suitability claims.
- Egress-code compliance claims.
- Security grades or forced-entry claims.
- Mortise depths or bolt lengths not taken from the maker’s template.
- Square-edge instructions applied to rebated or astragal edges.
- Surface bolt or storefront glass-rail procedures.
- Instructions that skip the template.

After the list check, install a bolt on a sample leaf following only the sheet and the template. If the bolt reaches both strikes and the leaf holds, the sheet is ready.
Industry references
Door hardware in the United States is commonly specified against ANSI/BHMA standards, maintained by the Builders Hardware Manufacturers Association. The sheet should not claim a grade unless the bolt is certified.
Sign-off
The brand approves the wording and the maker confirms the template and strike data. Koitor can review the install sheet against the packed bolt and flag code, security or edge-condition issues.
Frequently asked questions about flush bolts
Which door does a flush bolt go on?
The inactive leaf of a pair of doors, the one that normally stays closed while the active leaf opens.
Where on the door edge does the flush bolt go?
Near the top and bottom of the inactive leaf edge, at the positions shown on the maker’s template. The template also shows the clearance needed from the active leaf’s strike.
Do I need a top and a bottom flush bolt?
Many pairs use both, one into the head frame and one into the floor. Some use only one. The door details and the maker’s guidance decide.
What tools do I need to install a flush bolt?
Usually the maker’s template, a router or chisels for the mortise, a drill for the rod channel and strikes, and screwdrivers. Factory-prepared doors need fewer tools.
What is the difference between manual and automatic flush bolts?
Manual bolts are thrown by hand with a lever or slide. Automatic bolts project and retract when the active leaf closes and opens. Their installation and use differ.
What is a dust-proof strike?
A floor strike with a spring-loaded plunger that closes the hole when the bolt is withdrawn, keeping dirt out.
Can I fit a flush bolt to a rebated door?
Yes, if the bolt and face plate are designed for a rebated edge. Square-edge bolts will not sit correctly.
Why does my flush bolt not reach the strike?
The bolt may be too short for the door height or undercut, the strike may be in the wrong place, or the leaf may be warped. Check the bolt length against the maker’s chart and re-mark the strike with the door closed.
Can I replace a flush bolt with a surface bolt?
That changes the product and may not suit the door or its use. Use the hardware the door was specified for, and ask the building owner about any change.
Is a flush bolt allowed on a fire door?
Only listed hardware installed as part of the labeled assembly. This sheet excludes fire-rated pairs.
Does Koitor make flush bolts?
Koitor makes custom metal bathroom and home storage hardware and reviews install wording for parts in its programs. Whether a flush bolt is part of a specific program is confirmed on the packing list and quote.
Trabaja con Koitor Hardware
Review a flush bolt install sheet
Send the flush bolt drawing and template, the door and frame details and the current install sheet. We can review whether the wording names the bolt family, the leaf edge and the documented strikes. We will not issue fire-rating, egress-code or security claims.
OEM / MARCA BLANCA
Convierte esta guía de abastecimiento en un resumen del producto
Indícanos el producto que deseas, el tamaño, el acabado, la cantidad del pedido y los requisitos de embalaje. Tu equipo recibirá un análisis práctico de la viabilidad de fabricación antes de recibir el presupuesto.