Página inicial
Produtos
Armazenamento na casa de banho Armazenamento na cozinha Organizadores de duche Cestos de arame Toalheiros Ver todos os produtos
Fabrico por encomenda Fábrica Qualidade Blogue Contacto

Guias do comprador

How to Install a Magnetic Door Stop: Pair the Magnet and Catch First

An install sheet can only explain how to install a magnetic door stop once it names the two parts that were packed and where each one goes. A magnetic stop is a pair: a magnet body…

Wall-mounted and floor-mounted magnet bodies with matching door catch plates laid out to plan how to install a magnetic door stop

An install sheet can only explain how to install a magnetic door stop once it names the two parts that were packed and where each one goes. A magnetic stop is a pair: a magnet body fixed to the wall, the floor or a skirting board, and a catch plate fixed to the door. The pair only works when the two faces meet squarely at the open position.

Most problems reported by users come from treating the stop as a single bumper. The magnet is fixed first in a convenient spot, the door is swung open, and the catch ends up a few millimeters off. The door then bounces off the body or holds on one edge. The fix is in the sequence, and the sequence depends on the pair.

This guide is for importers, distributors and private-label teams selling magnetic door stops alone or as part of door hardware sets. Koitor Hardware is a family-owned China OEM manufacturer of custom metal bathroom and home storage hardware. The guide covers the install sheet; it is not a door stop catalog and not a holding-force specification.

Classification of door stop types is covered in the live types of door stops guide, which notes that “magnetic” describes the holding method rather than the mounting position. Folding magnetic holders are covered in magnetic folding door holder fit. This page is the first-hang sheet for a fixed two-part magnetic stop.

What does how to install a magnetic door stop depend on first?

It depends on the packed pair and the mounting surface. The pair tells the installer which part goes where and how it is fixed. The mounting surface decides which fixings in the bag are used and whether the packed fixings are suitable at all.

A wall-mounted magnet body usually projects from the wall at about the height where the door face will meet it, with the catch on the door face. A floor-mounted body sits on the floor and meets a catch on the bottom of the door face or the door edge. A skirting-mounted body is a variation of the wall type.

Each arrangement uses a different set of fixings. Wall bodies go into a stud, a hollow-wall anchor or masonry. Floor bodies go into timber, tile over concrete, or stone. Catches go into a solid timber door, a hollow-core door skin, or a metal door, and some kits offer adhesive pads instead of screws.

For a brand, the key question is what the listing can promise. “Easy to install” implies the packed fixings suit the surfaces the buyer has. If the kit only includes wood screws, a buyer with a hollow-core door and a tiled floor will need extra parts. The sheet should say which surfaces the packed fixings cover.

Start the sheet with a pair block. Show the magnet body and catch side by side, name the mounting position for each, and list the fixings that come with each part. If the supplier documents a body projection or a catch thickness, include it. Otherwise leave those fields named and blank.

Then add a surface block that lists which wall, floor and door types the packed fixings are intended for, using the supplier’s words. If a surface is not covered, say so and tell the reader they will need suitable fixings for it. Do not imply that the screws in the bag work everywhere.

How is a magnetic stop pair different from a bumper or a folding holder?

A bumper stop only stops the door. A magnetic stop stops it and holds it. That second job is why alignment matters, and why the sheet needs more care than a single-part stop. A folding holder is a different product again, with a hinged arm that drops to prop the door.

Single-part bumpers

A floor or wall bumper is one part fixed in one place. The door touches it and stops. The only alignment question is whether the door face or handle reaches it first. Height and contact for floor bumpers are covered in floor door stop height and contact buyer checks.

Two-part magnetic pairs

A magnetic stop works only when the catch plate lands flat on the magnet face. If the catch lands at an angle, the holding contact drops sharply and the door may bounce or drift. That is why the catch is located from the magnet, not measured independently on the door.

The practical sequence many supplier sheets follow is to fix the magnet body first, open the door to the intended stop position, mark where the door meets the body, and then fix the catch at that mark. The sheet should copy the supplier’s sequence and keep that marking step explicit.

Folding magnetic holders

A folding holder uses a pivoting arm or plate that can be stowed or dropped. Its install and fit questions, including the notes that it is not an installation manual and excludes fire and smoke doors, are on the magnetic folding door holder fit page. This install sheet should not mix the two.

Hinge pin stops

A hinge pin door stop fits on the hinge and limits the swing at the hinge side. Its first-hang sheet is the published how to install a hinge pin door stop guide. If a buyer is choosing between a hinge pin stop and a magnetic stop, the classification guide is the place to compare them.

Hands holding a door catch plate against the door face to mark where it meets a wall-mounted magnet body
Mark the catch where the door actually meets the magnet body, with the door at its intended open position.

What should a magnetic door stop install sheet list?

A complete sheet is short, but each field matters. The table below is a template for the kit and surface section, followed by the steps. It contains no holding force, no projection values and no screw sizes, because those belong to the supplier’s data for a named part.

Campo What to write Source
Magnet body Wall, floor or skirting body, with the supplier’s part name Packing list and drawing
Door catch Plate or cup, screw-fixed or adhesive, with mounting face Packing list and drawing
Fixings packed Screws, plugs, anchors or adhesive pads for each part Packing list
Surfaces covered The wall, floor and door types the packed fixings are intended for Supplier sheet
Alignment step Fix the body, open the door to the stop position, mark the catch Supplier sheet
Door clearance check Confirm the handle or lever does not hit the wall before the catch meets the body Supplier sheet; general practice
Exclusions Fire doors, smoke doors and any door with a required hold-open device Brand policy

Order the steps around the mark

The marking step is the heart of the sequence. Everything before it prepares the body; everything after it fixes the catch. A sheet that tells the user to measure the catch height on the door before the body is fixed invites a misaligned pair.

Check the handle and door swing

A magnetic stop sets the open position of the door. If the handle hits the wall before the catch meets the body, the stop is in the wrong place or projects too little. The sheet should ask the installer to check handle clearance before drilling, and to choose a different body if needed.

Cover adhesive catches honestly

Some kits include adhesive pads for the catch on doors where screws are unwanted. Adhesive performance depends on the door surface, cleaning and temperature. The sheet should copy the supplier’s surface preparation instructions and avoid saying adhesive is equivalent to screws unless the supplier states it.

Floor-mounted bodies and cleaning

Floor magnets sit where they are cleaned, mopped and kicked. The sheet can mention that the body should be positioned so it is not a trip hazard in the walking path, which is general good practice, and follow the supplier’s fixing for the floor type.

A typical wall-mounted sequence

For a wall-mounted pair, a typical documented sequence runs in six steps. Open the door to the position where it should stop, check the handle clearance, and mark the wall where the door face will meet the body. Fix the body at that mark using the fixing suited to the wall.

Next, close the door partway and open it again slowly until it touches the body. Mark the door face where the body’s magnet lands. Fix the catch at that mark, then test by opening the door several times and watching whether the catch lands flat. Adjust only in the ways the supplier allows.

The sheet should print the supplier’s own version of this sequence. The value of describing it here is to show what a complete sequence includes: a stop position, a clearance check, a body mark, a catch mark taken from the body, and a test.

A typical floor-mounted sequence

A floor-mounted pair follows the same logic at a different height. The body goes on the floor where the bottom of the door face or the door edge will reach it, and the catch goes at the bottom of the door. Door undercut and floor coverings matter here, because a thick rug or a threshold can change where the door meets the body.

The sheet should ask the installer to check the door bottom clearance over the floor finish before drilling, and to account for any floor covering that will be added later. If the supplier documents spacers or different body heights, they belong in this part of the sheet.

Testing after installation

A short test step closes the sequence. Open the door to the stop several times at normal speed and check that it holds and releases without the catch scraping. If it does not, recheck the marks before changing fixings. The sheet should describe what a correct install looks like, not a force value.

How should hollow doors, tiles and masonry be handled on the sheet?

These surfaces are where most installs go wrong, and they are also where the packed fixings are most likely to be unsuitable. The sheet should name them directly and tell the user what the kit does and does not cover.

Hollow-core doors

A hollow-core door has thin skins over a light core. Screws for a catch plate may hold poorly, especially near the middle of the door. Some suppliers recommend adhesive catches or specific fixings for hollow doors. The sheet should copy that advice or say hollow doors are not covered by the packed screws.

Metal doors

Metal doors may need self-tapping screws or adhesive, and some have internal reinforcement only in specific areas. The sheet should not invent drilling advice for metal doors. If the supplier does not cover them, list metal doors as needing project-specific fixings.

Tiled floors and walls

Drilling tile needs the right bit and care to avoid cracking, and the fixing goes into the substrate below. If the kit includes masonry plugs, the sheet can say so. It should not describe tile drilling technique in detail, which is a separate trade skill.

Hollow walls

A wall-mounted body on drywall should go into a stud where possible, or into a hollow-wall anchor suited to the job. A door swinging into a magnet loads the fixing every time it closes, so the anchor choice matters. Anchor selection belongs to the anchor documentation, not to this sheet.

Kits sold in multi-packs

Hotels, offices and rental programs often buy magnetic stops in multi-packs for many doors. In that setting the sheet is used by a maintenance team, and the main risk is applying one mounting height to every door. Doors differ in handle position, swing and floor finish, so the marking step has to be repeated at every door.

A one-page card with the pair, the surfaces covered, the marking step and the exclusions works well for those teams. It should carry the same version as the full sheet and the bill of materials, so a change in body or catch design is reflected everywhere.

Replacement catches and bodies

Buyers sometimes order spare catches or bodies separately. A spare only works if it matches the face and magnet design of the installed part. The sheet or the spare-part listing should name the pair it belongs to, rather than calling every catch universal.

Which doors and uses must the sheet exclude?

A magnetic door stop holds a door open. For ordinary interior doors that is a convenience. For fire doors and smoke doors, holding the door open can defeat their purpose, and those doors are governed by fire-door rules and listed hold-open devices.

In the United States, fire doors are covered by NFPA 80, the standard for fire doors and other opening protectives. A residential or commercial accessory magnet is not a listed hold-open device. The sheet should exclude fire and smoke doors in plain words and give no steps for them.

The sheet should also avoid suggesting the stop can be used on doors that must close automatically for any reason, such as doors with closers in commercial buildings, unless the supplier documents that use. When in doubt, the building manager or fire safety adviser decides, not the accessory leaflet.

Holding force claims

Holding force is the most common unsupported claim on magnetic stops. A number on a listing implies a test method, a door weight and a contact condition. Unless the supplier provides a tested value with its conditions, the sheet should not print one.

Exterior doors and wind

Exterior doors can be pushed by wind. A magnetic stop is not a wind restraint, and the sheet should say so if exterior use is mentioned at all. Storm door wind chains and similar restraints are different products.

Child safety and pinch points

Magnetic stops are sometimes marketed for keeping doors from slamming on fingers. That is a safety claim. Unless the brand has tested and documented it, the sheet should describe the product as a door stop and holder only.

What must a magnetic door stop install sheet not print?

The risky lines are short and usually copied from listings. Check the sheet against this list and remove or cite anything that matches.

  • A holding force or strength number without the supplier’s test conditions.
  • Any statement that the stop is suitable for fire doors, smoke doors or required hold-open use.
  • A universal mounting height or projection not taken from the supplier’s drawing.
  • Claims that the packed screws work on every wall, floor and door type.
  • Folding-holder or hinge-pin stop steps copied into the magnetic stop sequence.
  • Child safety, anti-slam or wind restraint claims without the brand’s own testing.
Clipboard checklist with a magnet body, catch plate and screws used to review a magnetic door stop install sheet
The install sheet names the pair, the mounting surface, the fixings and the exclusions before the steps.

Then read the sheet with the packed pair in hand and a sample door and wall in mind. Each step should match a part, a surface and the marking sequence. If a step only makes sense for a single bumper, it belongs to a different sheet.

Translation and pictograms

Magnetic stops are often sold with pictogram-only leaflets. If the brand adds text, make sure the pictogram for the marking step is clear: body fixed, door opened, catch marked. That single drawing does more than any paragraph to prevent misaligned installs.

Standards and industry references

Door hardware in the United States is often specified against ANSI/BHMA standards. The Builders Hardware Manufacturers Association is the body behind those standards. An accessory sheet should not claim BHMA certification unless the product has it.

Sign-off

The brand approves the wording and the supplier confirms the part data. Koitor can review the install sheet against the packed pair and flag missing surface notes or unsupported claims.

Frequently asked questions about magnetic door stops

Should the magnet go on the wall or the floor?

That depends on the packed body and the room. Wall bodies suit doors that open against a wall; floor bodies suit doors that open into open space. The supplier’s drawing decides which body is in the kit, and the sheet should not offer both unless both are packed.

How do I line up the catch with the magnet?

Fix the magnet body first, open the door to the intended position, and mark where the door meets the body. Fix the catch at that mark. This is the step most installs skip, and it is the main cause of doors that bounce off the magnet.

Can I use a magnetic door stop on a hollow door?

Possibly, but the packed screws may not hold well in thin skins. Follow the supplier’s advice for hollow doors, which may be an adhesive catch or a different fixing. If the supplier does not cover hollow doors, the sheet should say so.

What if the door bounces off the magnet?

The catch is probably not landing flat on the magnet face. Recheck the marking step with the door opened slowly to the body. Misalignment by a small amount is enough to cause bouncing, and moving the catch usually fixes it.

Is a magnetic door stop allowed on a fire door?

The sheet should exclude fire and smoke doors. Those doors are governed by fire-door rules and use listed hold-open devices where holding open is allowed. An accessory magnet is not one of those devices.

Do I need a stud for a wall-mounted magnet?

A stud gives the most solid fixing, but it is not always where the door meets the wall. If the body must go between studs, use a hollow-wall anchor suited to repeated impact, chosen from the anchor documentation. The sheet should say which wall fixings the kit includes and which it does not.

How strong is the magnet?

Only the supplier’s tested data can answer that, with its test conditions. A sheet without that data should not print a strength figure.

Does Koitor make magnetic door stops?

Koitor makes custom metal bathroom and home storage hardware and reviews install wording for parts in its programs. Whether a magnetic stop is part of a specific program is confirmed on the packing list and quote.

Trabalhe com a Koitor Hardware

Review a magnetic door stop install sheet

Send the magnet body and catch drawings, the packing list and the current install sheet. We can review whether the wording names the pair, the mounting surface and the documented alignment. We will not issue a holding-force rating or any fire or smoke door approval.

OEM / MARCA PRÓPRIA

Transforme este guia de fornecimento num resumo do produto

Indique o produto pretendido, as dimensões, o acabamento, a quantidade a encomendar e os requisitos de embalagem. A sua equipa receberá uma análise prática da viabilidade de fabrico antes da apresentação do orçamento.